        Introduction
        Intelligent detection module DV-PHM100 is an intelligent module for pharmaceutical production line quality inspection based on fast deep learning technology. Due to its characteristics of small size, easy expansion, convenient installation, strong AI computing power and high accuracy, it is more suitable for single-station and multi-station combination defect identification quality inspection for any working procedure of tablets, capsules and blistering medicine machines in the production process. At present, it has been widely used in the world's top pharmaceutical companies and received consistent praise.
        Detection range
        • Bubble plate

        • Pill Box

        • OCR

        Features
        • Flexible mounting base can be adapted
          to different scenes

        • Small appearance, to meet the complex
          space

        • According to the channel, flexible
          matching

        • No special care, simple
          maintenance

        • Fashionable, beautiful and
          atmospheric

        • It has the function of remote maintenance
          and debugging

        Parameters
        Indicator Definition
        Object Blister plate/OCR Pill Box/OCR
        Type PillCavitation, breakage, foreign body, hair, pressure bubble,
        mixed piece, fracture, codeword missing, color difference,
        Stains, black spots, etc
        Pill Box The medicine box is damaged, the medicine box is dirty,
        the medicine box is opened or partially opened,
        the medicine box is blackpoint, the sealing label
        is missing or partially damaged, the sealing
        label is offset, the sealing label is curled or wrinkled,
        and the medicine box is packaged in reverse
        CapsuleLong cap, short cap, split, missing cap, rubber,
        capsule deformation, residual powder, etc
        Bubble
        Plate
        Aluminum foil breakage, PVC folds, PVC black spots,
        aluminum foil scratches, drug plate deformation, rough edges,
        aluminum foil deviation, small horn, unclear mesh,
        false sealing, other unknown foreign bodies, etc
        OCROCR misprint, OCR blurry print
        Options Head/back Side/head/back
        Speed ≤700 plate/min(It depends on the specific detection content)
        Size range Width≤150mm,Height≤100mm
        Accuracy ≥99.99%
        Precision 0.12mm*0.12mm
        Common defect
        • Defect

        • Blot

        • Variant

        • Split

        • Vitium

        • Breakage

        • Variant

        • PVC Fold

        Introduction
        DV-PH700 is a bubble cap board visual sorting standard equipment based on deep learning technology. The equipment is fully equipped. The blanking and sorting system can complete the defect identification and sorting work independently or with the bubble hood machine. More suitable for pharmaceutical manufacturing plants with off-line or independent separation requirements, and It can be conveniently modified to line detection mode at any time.
        • Big data analysis screen

        • AI power control center

        • NG product waste bin

        • Connected to the feeding port

        • Visual module and motion center

        • Touch Control system screen

        • OK product outlet

        Detection range
        • Bubble plate

        • OCR

        Features
        • Flexible mounting base can be adapted
          to different scenes

        • Small appearance, to meet the complex
          space

        • According to the channel, flexible
          matching

        • No special care, simple
          maintenance

        • Fashionable, beautiful and
          atmospheric

        • It has the function of remote maintenance
          and debugging

        Parameters
        Indicator Definition
        Object Blister plate/OCR
        Type PillCavitation, breakage, foreign body, hair, pressure bubble, mixed piece, fracture, codeword missing, color difference,Stains, black spots, etc
        CapsuleLong cap, short cap, split, missing cap, rubber, capsule deformation, residual powder, etc
        Bubble
        Plate
        Aluminum foil breakage, PVC folds, PVC black spots, aluminum foil scratches, drug plate deformation, rough edges, aluminum foil deviation, small horn, unclear mesh, false sealing, other unknown foreign bodies, etc
        OCRNo batch number, batch number fuzzy, batch number printing skew, batch number offset, batch number character omission, batch number character punch through, etc
        Options Head/back Side/head/back
        Speed ≤700 plate/min(It depends on the specific detection content)
        Size range Width≤300mm,Height≤100mm
        Accuracy ≥99.99%
        Precision 0.12mm*0.12mm
        Common defect
        • Fracture

        • Mixed

        • Code missing

        • Defect

        • Shading

        • Blot

        • Foreign matter

        • Split

        • Grind

        • Short cap

        • Rubber

        • Breakage

        • Leak

        • Missing cap

        • Vague shape

        • Nick

        • PVC-Nick

        • Dim mesh

        Introduction
        The infrared thermal imager takes the thermal image of the mouth of the bottle after heat sealing, and transmits the thermal image to the image processing system for analysis and recognition. The temperature distribution of thermogram was analyzed statistically to determine the tightness of workpiece. Nonconforming products are removed and qualified products are sent to the next process.

        Features
        Extensive use:
        Suitable for aluminum foil electromagnetic sealing and heat sealing products, and suitable for all kinds of bottle caps/aluminum foil;
        Advanced technology, safe and reliable system, strong stability:
        Using the most advanced infrared thermal imaging equipment in the industry, the highest frame speed of 55 frames. The thermal image is captured in micro, the algorithm is developed from the bottom, safe and stable;
        Customized algorithm, more suitable for customer needs;
        The operation interface is simple and easy to operate;
        Image what you see is what you get, real-time monitoring; The data are saved in real time and can be traced to facilitate the analysis of causes of nonconforming products;
        System setup and verification in accordance with FDA21CFR PART 11。
        Parameters
        Indicator Definition
        Speed ≤18m/min( conveyor )
        Applicable lid specification Diameter :20mm~200mm;
        Shape : round
        Structure :CT/CRC;
        Color : Except black
        Applicable filling form Tablets, soft/hard capsules, liquid, powder
        Applicable aluminum foil form A combination of single aluminum foil, paper pad and aluminum foil
        Applicable bottle size Diameter≤300mm; Height≤500mm; Interval≥12mm
        Installation location Within 0.2m after the electromagnetic induction/heat sealing machine in the production site
        Indicator Indicator Definition

        Lidless

        Sealing machine power is too small resulting in bad sealing

        Sealing machine power is too large, resulting in aluminum foil burn

        Aluminum foil and insulation paper inverted, loose cover, crooked cover

        Aluminum foil edge is broken or missing

        Aluminum foil free
        Introduction
        DV-XRAY100 is a standard equipment for visual sorting of double aluminum foam plate based on X-ray perspective technology. The device can recognize and sort defects independently or with a bubble hood machine.
        It is more suitable for the pharmaceutical production workshop with off-line or independent separation requirements, and can be easily modified to line detection mode at any time.
        • Big data analysis screen

        • AI power control center

        • NG product waste bin

        Detection range
        • Bubble plate

        • OCR

        Features
        High sensitivity and stability
        High speed fluoroscopy detection and elimination
        Structural parts and contact parts conform to GMP drug standard materials
        Parameters
        Indicator Definition
        Object Double aluminum blister plate
        Type Troche Cavitation, breakage, lobes, foreign bodies
        Capsule Cavitation, breakage, lobes, foreign bodies
        Speed ≤300plate/min(It depends on the specific detection content)
        Size range Width≤240mm,Height≤120mm
        Accuracy ≥99.99%
        Precision SUS 304 ball:Φ0.3mm, Wire:Φ0.2×2mm, Ceramic glass:Φ1.0mm
        Common defect
        • Vacuolar sac

        • Breakage

        • Foreign matter

        • Incomplete

        • Ceasma

        AV免费网址在线观看